Avaya 03-300430 User Manual

Page of 2574
SNI-BD (SNI Circuit Pack)
Issue 1 June 2005
2087
 
120
FAIL
The SNI circuit pack cannot communicate with the equipped SNI in slot 
20.
1. Perform the 
 procedure in Maintenance 
Procedures (03-300192). This will resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER Error Type 3841, replace the 
SNI being tested. Replacing an SNI may be service interrupting. See 
on page 2046 for the procedure for 
replacing an SNI. To view SNI-PEER errors, use display errors 
with category PNC-PEER. Retry the command.
3. If the SNI being tested has SNI-PEER Error Type 3841, replace the 
SNI in slot 20. Replacing an SNI may be service interrupting. See 
on page 2046 for the procedure for 
replacing an SNI. Retry the command.
133
FAIL
No neighbor link is administered, but the SNI has an EI neighbor.
1. Administer the SNI on a fiber link to the EI neighbor it is connected to 
using add fiber-link next. Or remove both fiber endpoints (i.e., 
this SNI and its EI neighbor) and remove the fiber endpoints from 
circuit pack administration using change circuit-pack.
134
FAIL
No neighbor link is administered, but the SNI has an SNI neighbor.
1. Administer the SNI on a fiber link to the SNI neighbor it is connected 
to using add fiber-link next. Or remove both fiber endpoints 
(i.e., this SNI and its SNI neighbor) and remove the fiber endpoints 
from circuit pack administration using change circuit-pack.
135
FAIL
The SNI circuit pack cannot communicate with its neighbor. The SNI has 
an administered neighbor, but cannot communicate with its neighbor.
1. Check if the administered neighbor is inserted. If not, insert the 
neighbor circuit pack.
2. Perform the 
 procedure in Maintenance 
Procedures (03-300192).
136
FAIL
The SIN’s administered neighbor does not match the physical neighbor 
connected. The type of neighbor administered is an SNI and the type of 
neighbor physically connected is an EI.
1. Enter list fiber-link, and verify that the fiber-optic and metallic 
cable connections are installed as administered.
Table 752: TEST #759 Configuration Audit  (continued)
Error
Code
Test
Result
Description / Recommendation
 11 of 13