Avaya 03-300430 User Manual

Page of 2574
SNI-BD (SNI Circuit Pack)
Issue 1 June 2005
2093
 
Packet Neighbor Link Test (#767)
This test is nondestructive.
This test checks the packet path of the neighbor circuit pack and the peer circuit packs. A 
packet is sent from the SNI being tested to the peer SNIs and to the neighbor EI or SNI. If the 
other EI or SNI sends the same data back in the packet, this test passes. Otherwise, this test 
fails.
Table 754: TEST #767 Packet Neighbor Link Test 
Error
Code
Test
Result
Description / Recommendation
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2300
ABRT
The downlink message necessary to run this test could not be sent.
1. Retry the command at 1-minute intervals up to 3 times.
2301
ABRT
The software timer could not be set before sending the downlink message 
necessary to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2302
ABRT
Software received incorrect message data from the SNI circuit pack.
1. Retry the command at 1-minute intervals up to 3 times.
2303
ABRT
The SNI circuit pack responded that the software test requested is invalid.
1. Retry the command at 1-minute intervals up to 3 times.
2304
ABRT
SNI firmware is not able to run the test. For this particular test, the SNI 
circuit pack must be able to communicate with its neighbor.
1. Verify that the SNI can communicate with its neighbor by checking the 
yellow LED of the SNI to make sure the SNI is in frame, or by running 
test board for the SNI and checking test 989 for fiber out-of-frame. 
If the results of Test 989 indicate that the fiber is out-of-frame, follow 
the recommendation associated with the test failure. If a DS1 
converter complex exists on the fiber link, enter display errors 
and follow the repair procedures for any DS1C-BD and DS1-FAC 
entries.
2. Retry the command at 1-minute intervals up to 3 times.
 1 of 12