Avaya 03-300430 User Manual
SNI-BD (SNI Circuit Pack)
Issue 1 June 2005
2095
102
FAIL
The SNI circuit pack cannot communicate with the SNI in slot 2 over the
packet path.
packet path.
1. Fix any on-board SNI-BD errors against this SNI and the SNI in slot 2.
Use the display errors command to find any SNI-BD errors and
use the display alarms command to determine whether the errors
have on-board alarms. Then, follow the repair procedures for the
SNI-BD as described in the Maintenance manual.
have on-board alarms. Then, follow the repair procedures for the
SNI-BD as described in the Maintenance manual.
2. Use display errors to check the error log for other SNI circuit
packs with SNI-PEER Error Type 1. If other SNI circuit packs have
SNI-PEER Error Type 1 errors, replace the SNI in slot 2. Replacing an
SNI may be service interrupting. See
SNI-PEER Error Type 1 errors, replace the SNI in slot 2. Replacing an
SNI may be service interrupting. See
page 2046 for the procedure for replacing an SNI.
If other SNI circuit packs do not have SNI-PEER Error Type 1 errors, the
problem could be at either of the peer SNI boards. It is arbitrary as to which
SNI is replaced first.
3. Replace the SNI being tested.
4. Replace the SNI in slot 2.
103
FAIL
The SNI circuit pack cannot communicate with the SNI in slot 3 over the
packet path.
packet path.
1. Fix any on-board SNI-BD errors against this SNI and the SNI in slot 3.
Use display errors to find any SNI-BD errors and use the display
alarms command to determine whether the errors have on-board
alarms. Then, follow the repair procedures for the SNI-BD as
described in the Maintenance manual.
alarms. Then, follow the repair procedures for the SNI-BD as
described in the Maintenance manual.
2. Use display errors to check the error log for other SNI circuit
packs with SNI-PEER Error Type 257. If other SNI circuit packs have
SNI-PEER Error Type 257 errors, replace the SNI in slot 3. Replacing
an SNI may be service interrupting. See
SNI-PEER Error Type 257 errors, replace the SNI in slot 3. Replacing
an SNI may be service interrupting. See
page 2046 for the procedure for replacing an SNI.
If other SNI circuit packs do not have SNI-PEER Error Type 257 errors, the
problem could be at either of the peer SNI boards. It is arbitrary as to which
SNI is replaced first.
3. Replace the SNI being tested.
4. Replace the SNI in slot 3.
Table 754: TEST #767 Packet Neighbor Link Test (continued)
Error
Code
Code
Test
Result
Result
Description / Recommendation
3 of 12