Avaya 03-300430 User Manual
SNI-PEER (SNI Peer Link)
Issue 1 June 2005
2113
SNI-PEER (SNI Peer Link)
S8700 MC
only
SNI Peers are Switch Node Interfaces residing on the same Switch Node Carrier. SNI-PEER
maintenance involves testing of the links between SNI Peers. SNI-PEER errors are described
on the following pages. For a full description of SNIs, including circuit pack replacement, see
maintenance involves testing of the links between SNI Peers. SNI-PEER errors are described
on the following pages. For a full description of SNIs, including circuit pack replacement, see
Error Log Entries and Test to Clear Values
MO Name
Alarm Level
Initial SAT Command to Run
Full Name of MO
SNI-PEER MAJ
test board location s
SNI Peer Link
SNI-PEER MIN
test board location s
SNI Peer Link
SNI-PEER WRN
test board location s
SNI Peer Link
Table 757: SNI-PEER Hardware Error Log Entries
Error
Type
Type
Aux
Data
Data
SNI
Slot
Slot
1
Associated Test
Alarm
Level
Level
On/Off
Board
Board
Test to Clear Value
0
2
0
Any
Any
Any
test board location r 1
1
Any
2
Failure audit (#777)
MAJ
MIN
WRN
OFF
test board location r 1
257
Any
3
Failure audit (#777)
MAJ
MIN
WRN
OFF
test board location r 1
513
Any
4
Failure audit (#777)
MAJ
MIN
WRN
OFF
test board location r 1
769
Any
5
Failure audit (#777)
MAJ
MIN
WRN
OFF
test board location r 1
1025
Any
6
Failure audit (#777)
MAJ
MIN
WRN
OFF
test board location r 1
1 of 2