Notes:
For every error in 
circuit pack reporting the error indicates that it has a problem with the control path, circuit path, 
or packet path to the SNI peer in the slot indicated on the error table.
1. Run the Failure Audit test (#777) to confirm if the error still exists.
2. If the SNI reports an SNI-PEER error against a slot that does not contain an SNI, either 
change circuit pack administration using change circuit-pack to un-administer the 
SNI, or insert an SNI into the indicated slot. Use list configuration carrier to 
determine if an SNI circuit pack is inserted. Otherwise, use display errors and look at 
every SNI-PEER error in the log. If either of the following two conditions are present, follow 
Do many SNIs have SNI-PEER errors pointing to the same 2 adjacent SNIs?
Do 2 adjacent SNIs have SNI-PEER errors pointing to many other SNIs?
3. If neither condition is present, follow 
 below. When using either procedure, see 
page 2000 for circuit pack replacement instructions.
Procedure 1
Proceed through the following steps until the problem is resolved:
1. Perform the 
 procedure in Maintenance Procedures (03-300192).
2. Replace the SNI pointed to by the SNI-PEER Error Type (see the SNI Slot column in 
3. Replace the SNI reporting the SNI-PEER error.
4. Replace the active SNC.
Slot Numbers of 
Adjacent SNIs
Point to this SNI Pair
2, 3
1, 257
4, 5
513, 769
6, 7
1025, 1281
8, 9
1537, 1793
13, 14
2049, 2305
15, 16
2561, 2817
17, 18
3073, 3329
19, 20