Avaya 03-300430 User Manual

Page of 2574
STRAT-3 (Stratum-3 Clock)
Issue 1 June 2005
2131
 
The output of the CI and PAI cards go directly to the TN780 Tone-Clock circuit pack via two 
25-pair amphenol terminated cables. Every card has red and/or green LEDs for providing status 
or alarm indications. The abbreviations used in the table are defined above except for SRC 
(source) and PLL (Phase Locked Loop).
Table 763: Stratum-3 Clock LED Indications
Card
Name
Color
Indication
PAI
REF A
Red
Loss of input reference A or CI A failed
REF B
Red
Loss of input reference B or CI A failed
ST A
Red
Failed Stratum-3 clock A
ST B
Red
Failed Stratum-3 clock B
PWR A
Green
-48VDC A present
PWR B
Green
-48VDC B present
CI
FAIL
Red
Card failure
DS1
Green
DS1 source present
CC
Green
Composite clock source
1
 present
1. Composite Clock (CC) source refers to the protocol used to electrically transfer timing 
from the Stratum-3 clock to the switch. The Composite Clock source is not relevant to the 
system.
SRC 
ACTIVE
Green
Card is currently on-line
ST3
FAIL
Red
Card failure
LOCK
Red
PLL lost sync with reference or holdover 
mode
REF A
Red
Timing Reference from CI A
REF B
Red
Timing Reference from CI B
TOC
FAIL
Red
Card failure
PORT ALM
Red
Output port alarm (one or more)
ST
Green
Reference present from ST clock
INPUT
Green
Reference present from CI
500’
Green
500-foot phase advance
1000’
Green
1000-foot phase advance