Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
2156 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Figure 131: Synchronization Troubleshooting, Fig. 2 of 4
Examine cabinet’s
2
Slips on DS1
facilities?
Retranslate to
according to the
network’s plan.
Is this DS1
supposed to be PN’s
No
Yes
Yes
No
From
Fig 1
Refer problem for 
investigation at other
 
 
end of facility.
have DS1 operate
synchronization plan.
A
No
role in network’s
timing reference?
Yes
No
Problem is in PN,
IPSI’s Tone-Clock
Escalate
or DS1s.
Slips on IPSI’s 
Tone-Clock circuit? 
Done