SYNC (Port-Network Synchronization)
Issue 1 June 2005
2167
 
Notes:
a. Error Type 0: run the short test sequence first. If every test passes, run the long test 
sequence. Refer to each test’s description, and follow its procedures.
b. Error Type 1: run the short test sequence first. If every test passes, run the long test 
sequence. Refer to each test’s description, and follow its procedures.
This error indicates a problem with the primary DS1 reference. It is cleared when the 
primary reference is restored. To find the problem’s source:
1. Enter list configuration board location to check if the primary DS1 Interface 
circuit pack is inserted in the carrier.
2. Verify that the administered primary reference matches the DS1 reference from the 
network synchronization plan.
3. Enter test board location long to test the primary DS1 Interface circuit pack.
Check the Error Log for DS1-BD or UDS1-BD errors and see 
resolve errors associated with the primary DS1 (DS1 or UDS1) interface circuit pack.
If the only errors against DS1-BD or UDS1-BD are slip errors, follow the procedures 
described in the previous troubleshooting section. If no errors are listed in the Error Log 
for the primary DS1 Interface circuit pack, continue with the following steps.
None
WRN
MIN (
OFF
None
18 (
0
disable sync
WRN
OFF
enable sync
257 (
)(
)
None
WRN
MIN (
OFF
None
513 (
)(
)
None
WRN
MAJ (
OFF
None
769 (
)
None
MAJ
OFF
None
1793 (
)
1
0–50
None
MAJ
OFF
None
2049 (
)
0
None
WRN
OFF
None
1. It can take up to 1 hour for these alarms to clear.
Table 771: Synchronization Maintenance Error Log Entries (continued)
Error
Type
Aux
Data
Associated Test
Alarm 
Level
On/Off
Board
Test to Clear Value
 2 of 2