System Link Status (#985)
This test is nondestructive. This test queries the switch for the status of the system link and 
verifies that every switch component has the same view of the link state.
Table 775: TEST #985 System Link Status 
Error
Code
Test
Result
Description / Recommendation
1007
ABRT
Could not locate the system link associated with this location
1. Retry the command at 1-minute intervals up to 5 times.
2500
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
6
FAIL
The system link is down.
1. Follow the procedure for Error Type 13.
PASS