2194 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Hardware Error Log Entries and Test to Clear Values
S/T
4-wire Basic Rate connection to an NT2 Termination
1
.
4-wire Basic Rate interface to an NT Termination.
2
TE
Terminal Equipment
Basic Rate network-side 2-wire line interface.
1
TN556B ISDN-BRI 4-Wire S/T-NT Line (A-law)
2
TN2185 ISDN-BRI 4-Wire S Interface (Trunk Side)
3
TN2198 ISDN-BRI 2-Wire U Interface
5
TN2185 ISDN-BRI 4-Wire S Interface (Trunk Side)
1. Network Termination 2 (NT2), that terminates Layer 1 and higher layers. PBXs, LANs, and 
terminal controllers typically provide NT2 functionality including protocol handling and 
multiplexing for Layers 2 and 3.
2. Network Termination 1 (NT1), that terminates Layer 1 and monitors maintenance, 
performance, timing, power transfer, multiplexing, and multidrop termination with contention 
resolution.
 2 of 2
Table 783: TBRI-BD Error Log Entries 
Error
Type
Aux 
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0 (
0
Any
Any
Any
test board location sh r 1
1 (
Any
None
MIN
ON
257 (
65535
Control Channel Loop (#52)
MIN
ON
test board location r 20
513 (
4352 -
4357
None
ON
769 (
4358
1025 (
NPE/NCE Audit test (#50)
None
ON
1291 (
4359
Clear Error Counters (#270)
MIN
ON
1294 (
46088 -
46096
SAKI Sanity test (#53)
MIN
ON
 See (h)
 1 of 2