Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
2202 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Figure notes:ISDN Interface Reference Point definitions
Hardware Error Log Entries and Test to Clear Values
LT
Logical Terminal
Primary Rate user/network (asymmetrical) trunk interface. The ECS is capable of acting 
as the user or as the network side of this 1.544 or 2.048-Mbps interface.
R
Interface between Terminal Equipment and Network Termination
S
Basic Rate network-side 4-wire line interface
S/T
4-wire Basic Rate connection to a NT2 Termination
1
.
1. Network Termination 2 (NT2), that terminates Layer 1 and higher layers. PBXs, LANs, and terminal 
controllers typically provide NT2 functionality including protocol handling and multiplexing for Layers 2 
and 3.
4-wire Basic Rate interface to a NT1 Termination.
2
2. Network Termination 1 (NT1), that terminates Layer 1 and monitors maintenance, performance, timing, 
power transfer, multiplexing, and multi-drop termination with contention resolution.
TE
Terminal Equipment
Basic Rate network-side 2-wire line interface.
1
TN556B ISDN-BRI 4-Wire S/T-NT Line (A-law)
2
TN2185 ISDN-BRI 4-Wire S Interface (Trunk Side)
3
TN2198 ISDN-BRI 2-Wire U Interface
5
TN2185 ISDN-BRI 4-Wire S Interface (Trunk Side)
Table 785: TBRI-PT Error Log Entries 
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0 (
0
Any
Any
Any
test port location sh r 1
1 (
Level 1 Status test (#1242)
MIN
OFF
129 (
)
257(
 
 1 of 2