Avaya 03-300430 User Manual

Page of 2574
TBRI-PT (ISDN Trunk-Side BRI Port)
Issue 1 June 2005
2217
 
Level 1 Status Query Test (#1242) 
This test is conditionally destructive.
Note:
Note:
S8300
 / 
G700
: This test aborts with Error Code 1412 on a G700 Media Gateway.
This test determines the state of the transmission facility of a BRI port at the Level 1 (L1) 
physical layer: Activated, Pending Activation, or Deactivated.
The Activated state is the correct state for an ISDN-BRI port. In this state, the L1 interface can 
send and receive synchronized signals. This test passes if the state of L1 is Activated. This test 
also passes if software has taken this port out of service. See the description of the L1 
“Deactivated State” below for more details.
Table 792: Test #625 Receive FIFO Overflow Error Counter Test 
Error
Code
Test
Result
Description / Recommendation
2000
ABRT
Response to the test was not received from the circuit pack within the 
allowable time period.
1. If the test aborts repeatedly up to 5 times, reset the circuit pack with 
busyout board location and reset board location.
2. If the test aborts again, replace the circuit pack.
2012
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
value
FAIL
The TBRI-BD circuit pack is still detecting errors of this type. The Error 
Code field contains the value of this counter.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to fail, run the long test sequence, and pay 
particular attention to the Loop-Around tests (#618 and #619). See the 
repair procedures for the executed test if it fails. Otherwise, go to the 
next step.
3. Replace the circuit pack.
PASS
The Receive FIFO Overflow error counter was read correctly and has a 
value of 0.