Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
2222 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
BRI Port Slip Query Test (#1244)
This test is nondestructive.
Slips occur when the transmitter and receiver are not running at precisely the same clock rate. 
The BRI Slip Query test polls the total number of slips that have occurred on a link.
When the TN2185 circuit pack detects a slip condition, maintenance software initiates the BRI 
Slip Query test to query the slip counters on the TN2185 circuit pack.
If the slip count is over the threshold, a MINOR alarm is raised against the TN2185 circuit pack, 
leaving every port of the TN2185 circuit pack in the in-service state. If the TN2185 circuit pack is 
used to supply the system synchronization source, the MINOR alarm will initiate a 
synchronization source switch. See 
on page 2143 for additional information.
Table 795: Test #1244 BRI Port Slip Query Test 
Error
Code
Test
Result
Description / Recommendation
 ABRT
Internal 
system 
error
1. Retry the command at 1-minute intervals up to 5 times.
2000
ABRT
Response to the test request was not received within the allowable 
time period. If Error Type 1538 is present in the Error Log, follow the 
maintenance strategy recommended for this Error Type.
2012
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
 1 of 2