Avaya 03-300430 User Manual
TBRI-TRK (Trunk-Side ISDN BRI Channel)
Issue 1 June 2005
2225
Hardware Error Log Entries and Test to Clear Values
Notes:
a. Error Type 0: run the Short Test Sequence first. If all tests pass, run the Long Test
Sequence. Refer to the appropriate test description and follow the recommended
procedures.
procedures.
b. Error Type 513: the far-end has reported that this channel is not administered. The trunks
are placed in the out-of-service state.
c. Error Type 1793: the signaling link is down:
●
Aux Data 8 indicates the Signaling Link is down.
●
Aux Data 9 indicates the Port is out of service.
d. Error Type 3073: the Service State Audit failed. The test will be run every 15 minutes until it
passes.
e. Error Type 3585: unexpected Restart message; this error causes no action and is logged
only.
f. Error Type 3841: B-Channel Rejection Event; this action causes the Service State Audit,
the Call State Audit, and the Test Call Audit to be executed.
Table 796: TBRI-TRK Error Log Entries
Error
Type
Type
Aux
Data
Data
Associated Test
Alarm
Level
Level
On/
Off
Board
Off
Board
Test to Clear Value
)
0
Any
Any
Any
test port location sh r 1
513 (
Service State Audit
(#256)
WRN
OFF
1793 (
)
8, 9
WRN
OFF
3073 (
)
Service State Audit
(#256)
3585 (
)
3841 (
WRN
OFF