Avaya 03-300430 User Manual

Page of 2574
TBRI-TRK (Trunk-Side ISDN BRI Channel)
Issue 1 June 2005
2225
 
Hardware Error Log Entries and Test to Clear Values
Notes:
a. Error Type 0: run the Short Test Sequence first. If all tests pass, run the Long Test 
Sequence. Refer to the appropriate test description and follow the recommended 
procedures.
b. Error Type 513: the far-end has reported that this channel is not administered. The trunks 
are placed in the out-of-service state.
c. Error Type 1793: the signaling link is down:
Aux Data 8 indicates the Signaling Link is down.
Aux Data 9 indicates the Port is out of service.
d. Error Type 3073: the Service State Audit failed. The test will be run every 15 minutes until it 
passes.
e. Error Type 3585: unexpected Restart message; this error causes no action and is logged 
only.
f. Error Type 3841: B-Channel Rejection Event; this action causes the Service State Audit, 
the Call State Audit, and the Test Call Audit to be executed.
Table 796: TBRI-TRK Error Log Entries 
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/
Off
Board
Test to Clear Value
)
0
Any
Any
Any
test port location sh r 1
513 (
Service State Audit 
(#256)
WRN
OFF
1793 (
)
8,  9
WRN
OFF
3073 (
)
Service State Audit 
(#256)
3585 (
)
3841 (
WRN
OFF