Communication Manager Maintenance-Object Repair Procedures
2264 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
TDM bus Clock PPM Inquiry Test (#150)
This test evaluates the quality of the synchronization source for the Tone-Clock circuit.
Table 810: Test #150 TDM bus Clock PPM Inquiry Test 
Error
Code
Test
Result
Description / Recommendation
ABRT
The system could not allocate the necessary resources for the test
1. Wait 1-minute, and retry the test.
1001
ABRT
The system could not allocate the necessary resources for the test.
1. Wait 1-minute, and retry the test.
255
ABRT
The test was not executed because the IPSI or Processor/Tone-Clock 
circuit pack was using its local oscillator rather than synchronizing to an 
external source.
1. Verify that this IPSI or Processor/Tone-Clock circuit pack is expected to 
be the synchronization source. If not, correct the synchronization 
information and re-execute the test.
2000
ABRT
Response to the test request was not received within the allowable time 
period.
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABRT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
Any
FAIL
The Error Code represents the rate (in Parts Per Million, or PPM) at which 
clock slip errors have been detected on the incoming synchronization 
source since the last PPM inquiry was sent to the IPSI or Processor/
Tone-Clock circuit pack. A failure of this test indicates that we are outside 
of (
S8700 MC
: Stratum-3) or Stratum-4 timing specifications on the incoming 
timing source.
The Error Code is a variable amount ranging from 1 to 254.
1. If error 1537 is entered in the hardware error log against TDM-CLK, 
then the board has switched timing sources. Follow the procedures 
associated with hardware log Error Code 1537.
2. Otherwise, see ‘‘Troubleshooting Approach’’ in the 