Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
2266 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
S8700 MC
Board Type Check Test (#574)
This test verifies that a Tone-Clock circuit pack administered with a Stratum-3 clock source has 
code TN780.
Table 812: Test #574 Board Type Check Test 
Error
Code
Test
Result
Description / Recommendation
2012
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
ANY
FAIL
Stratum-3 clock synchronization is administered for the carrier where this 
Tone-Clock circuit pack resides, but the Tone-Clock does not have code 
TN780.
1. If the Stratum-3 clock option is incorrectly administered, remove it.
2. Otherwise, replace the circuit pack. See 
 
PASS
The proper Tone-Clock circuit pack code (TN780) is present for Stratum-3 
clock synchronization.