TIE-DS1 (DS1 Tie Trunk)
Issue 1 June 2005
2283
 
0
NO 
BOARD
The test could not relate the internal ID to the port (no board). This 
could be due to incorrect translations, no board is inserted, an 
incorrect board is inserted, or an insane board is inserted.
1. Check to ensure that the board’s translations are correct. Use 
list configuration, and resolve any problems that are 
found.
2. If the board was found to be correctly inserted in step 1, enter 
busyout board location
3. Enter reset board location
4. Enter release board location
5. Enter test board location long. This should re-establish 
the linkage between the internal ID and the port. If this is not the 
case, check to see that there is a valid board inserted.
Table 816: Test #7 Conference Circuit Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 5 of 5