Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
2296 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
System Technician-Demanded Tests: Descriptions and Error 
Codes
Investigate tests in the order presented below. Clearing Error Codes associated with the one 
test may also clear errors generated from other tests in the sequence.
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND
1
1. D = Destructive; ND = Nondestructive
BRI Local LAN Port Loop Around Test (#618) 
Note: This Test ABORTS
X
D
BRI TDM Port Loop Around Test (#619) 
Note: This Test ABORTS
X
D
L1 State Query Test (#1242) 
Note: This Test ABORTS
X
X
D
CRC Error Counter Test (#623)
X
ND
Receive FIFO Overflow Test (#625)
X
ND
Layer 3 Query Test (#1243)
X
ND
Slip Query Test (#1244)
X
X
ND
Clear Error Counters Test (#270)
X
X
ND
NPE Crosstalk Test (#617) 
Note: This Test ABORTS
X
D