Table 826: TEST #1244 Slip Alarm Inquiry Test 
Error
Code
Test
Result
Description/ Recommendation
 
ABRT
Internal system error
2000
ABRT
Response to the test request was not received within the allowable time 
period. 
1. If Error Type 1538 is present in the Error Log, follow the 
maintenance strategy recommended for this Error Type.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
1 to 88
FAIL
The media module and the remote endpoint are not synchronized to the 
same clock rate, which has generated the Slip alarm. The Error Code 
equals the number of slips detected by the MM720 since the last Slip 
Alarm Inquiry Test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the media module is a MM720, enter the list measurement 
ds1-log GGGVSpp command to read the error seconds 
measurement.
3. Verify that both endpoints of the link are administered using the 
same signaling mode, framing mode, and line coding.
4. Check the physical connections of media modules and cable.
5. Replace the media module and repeat the test.
6. Contact Network Service to diagnose the remote endpoint.
 
PASS
No Slip alarm is detected on the media module.
0
NO
BOARD
The media module is not administered.
Run Test #53.