Communication Manager Maintenance-Object Repair Procedures
2304 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Additional in-line testing is performed whenever a call is in progress, logging errors that occur 
during operation. You can reproduce these types of errors by making a call over the trunk and 
then checking the Hardware Error Log.
By making translation and cross-connect changes, circuit packs (except for TN497) can be 
configured for back-to-back testing, also known as connectivity testing. Port operation is tested 
by connecting two tie trunk ports together in either E&M or simplex modes. See the section 
 in Maintenance Procedures (03-300192).
Error Log Entries and Test to Clear Values
Table 828: TIE Trunk Error Log Entries 
Error
Type
Aux
Data
Associated Test
Alarm 
Level
On/Off
Board
Test to Clear Value
0
Any
Any
Any
test port location sh r 1
16384
None
WRN
OFF
) 57476
None
WRN
OFF
) 57477
None
WRN
OFF
57483
None
WRN
OFF
57485
None
WRN
OFF
15 (
)
Any
Port Audit Update test 
(#36)
18 (
)
0
busyout trunk 
grp#/mem#
WRN
OFF
release trunk grp#/mem#
)
None
WRN
ON
test trunk grp#/mem#
)
57473
None
WRN
OFF
)
57474
None
WRN
OFF
)
57475
None
WRN
OFF
)
Any
EPF M and E Lead 
(#74)
MAJ
MIN
WRN
1
OFF
test port location sh r 3
)
57481
EPF M and E Lead 
(#74)
MAJ
MIN
WRN
ON
test port location sh r 3