Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
2312 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
1002
ABRT
The system could not allocate time slots for the test. The system may be 
under heavy traffic conditions or it may have time slots out-of-service due 
to TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic, 
repeat test at 1-minute intervals up to 5 times. 
1003
ABRT
The system could not allocate a tone receiver for the test. The system may 
be oversized force.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up 
to 5 times.
1004
ABRT
The port was seized by a valid call during the test. The test has been 
aborted. Use display trunk-group xx to determine the trunk group/
member number of the port. Use status trunk to determine the service 
state of the port. If the service state indicates that the port is in use, then the 
port is unavailable for certain tests. Wait until the port is idle before 
retesting.
1018
ABRT
The test has been disabled by administration.
1. Verify that the Maintenance Test field on the Trunk Group screen is n
To enable the test, use change trunk-group x where x is the 
number of the trunk group to be tested, and enter y in the 
Maintenance Test field.
2000
ABRT
Response to the test request was not received within the allowable time 
period.
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABRT
Could not allocate the necessary system resources to run this test. This 
could be due to a failure to seize the port.
1. Retry the command at 1-minute intervals up to 5 times.
Table 830: Test #33 Looparound and Conference Circuit Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 2 of 4