Avaya 03-300430 User Manual
TIE-TRK (Analog Tie Trunk)
Issue 1 June 2005
2319
1
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABRT
System resources required to run this test are not available. The trunk
may be busy with a valid call. Use display trunk-group xx to
may be busy with a valid call. Use display trunk-group xx to
determine trunk group/member number of the port. Use status trunk
to determine the service state of the port. If the service state indicates
that the port is in use, then the port is unavailable for certain tests. Wait
until the port is idle before retesting.
that the port is in use, then the port is unavailable for certain tests. Wait
until the port is idle before retesting.
1. If the port status is active, but the port is idle (no calls), then check the
Error Log for Error Type 1025 (see Error Log table for description of
this error and required actions). The port may be locked up. The
far-end PBX may not be releasing.
this error and required actions). The port may be locked up. The
far-end PBX may not be releasing.
2. If the port status is idle, then retry the command at 1-minute intervals
up to 5 times.
1004
ABRT
The port was seized by a valid call during the test. The test has been
aborted. Use display trunk-group xx to determine the trunk group/
aborted. Use display trunk-group xx to determine the trunk group/
member number of the port. Use status trunk to determine the
service state of the port. If the service state indicates that the port is in
use, then the port is unavailable for certain tests. Wait until the port is idle
before retesting.
use, then the port is unavailable for certain tests. Wait until the port is idle
before retesting.
1. Retry the command at 1-minute intervals up to 5 times.
1005
ABRT
This test is not valid for this trunk translation. Must be a type-1 standard
trunk for this test to run.
trunk for this test to run.
1. Check trunk configuration. If it is not a type-1 standard trunk, this
abort message should be ignored.
1014
ABRT
The test was aborted because the circuit pack has not been inserted into
the system.
the system.
1. Use list configuration board to ensure that the circuit pack is
inserted in the carrier.
2. If the board is not inserted, make sure the circuit pack is inserted in
the carrier and fully seated.
Table 833: Test #74 Tie Trunk EPF Test (continued)
Error
Code
Code
Test
Result
Result
Description / Recommendation
2 of 3