TIE-TRK (Analog Tie Trunk)
Issue 1 June 2005
2319
 
1
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABRT
System resources required to run this test are not available. The trunk 
may be busy with a valid call. Use display trunk-group xx to 
determine trunk group/member number of the port. Use status trunk 
to determine the service state of the port. If the service state indicates 
that the port is in use, then the port is unavailable for certain tests. Wait 
until the port is idle before retesting.
1. If the port status is active, but the port is idle (no calls), then check the 
Error Log for Error Type 1025 (see Error Log table for description of 
this error and required actions). The port may be locked up. The 
far-end PBX may not be releasing.
2. If the port status is idle, then retry the command at 1-minute intervals 
up to 5 times.
1004
ABRT
The port was seized by a valid call during the test. The test has been 
aborted. Use display trunk-group xx to determine the trunk group/
member number of the port. Use status trunk to determine the 
service state of the port. If the service state indicates that the port is in 
use, then the port is unavailable for certain tests. Wait until the port is idle 
before retesting.
1. Retry the command at 1-minute intervals up to 5 times.
1005
ABRT
This test is not valid for this trunk translation. Must be a type-1 standard 
trunk for this test to run.
1. Check trunk configuration. If it is not a type-1 standard trunk, this 
abort message should be ignored.
1014
ABRT
The test was aborted because the circuit pack has not been inserted into 
the system.
1. Use list configuration board to ensure that the circuit pack is 
inserted in the carrier.
2. If the board is not inserted, make sure the circuit pack is inserted in 
the carrier and fully seated.
Table 833: Test #74 Tie Trunk EPF Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 2 of 3