Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
2326 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
TIME-DAY (Time of Day)
S8700 | 8710
 / 
S8500
The time of day contains the current year, month, day of the week, day of the month, hour, 
minute, and second. The Time of Day MO monitors the time-of-day clock, and raises an alarm if 
the time-of-day clock is not set or cannot be read by the software. If the time-of-day clock is not 
set or cannot be read by the software, many features such as Time-of-Day Routing, CDR, ISDN 
Call-by-Call, and duplication, are inoperative or incorrect. Use set time to set the time-of-day 
clock when the system is initially powered up.
Use display time to read the time-of-day clock. Use set time to set the time-of-day clock. 
The time-of-day clock has a backup battery to save the time of day during power failures.
Error Log Entries and Test to Clear Values
a. Error Type 247: software cannot read the time-of-day clock. During this condition, every 
time stamp in Alarm Log entry, Hardware Error Log entry, and Software Error Log entry is 
potentially inaccurate. In addition, any features that are sensitive to the time of day (such as 
SMDR, Time-of-Day Routing, ISDN Call-by-Call) will not function correctly.
To resolve the alarm:
1. Use set time to set the time of day.
2. Use display time to display the time of day. If the time of day is displayed correctly, 
wait 15 minutes and verify that the alarm is retired.
MO Name
Alarm Level
Initial SAT Command to Run
Full Name of MO
TIME-DAY
MIN
set time
Time of Day
Table 835: Time-of-Day Error Log Entries
Error 
Type
Aux 
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
0
0
Any
Any
Any
display time
247 (
0
none
MIN
OFF
set time