Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
2352 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
None
FAIL
This Tone-Clock or IPSI circuit pack had an apparent loss of clock. One or 
more of Error Types 2049, 2305, 3834, 3857, 3858 and 3872 will appear in 
the error log. Correct the problem according to the appropriate error log 
entries.
Tone -Clock circuit pack – If this test fails for a Tone-Clock circuit pack, the 
only way to make it pass, and to retire its associated alarm, is to repair the 
problem and to execute set tone-clock location override against 
the indicated or Tone-Clock circuit pack.
IPSI’s Tone-Clock circuit – If this test fails for an IPSI circuit pack’s 
Tone-Clock circuit, the only way to make it pass, and to retire the associated 
alarm, is to repair the problem, and to execute  busy 
ipserver-interface, then enter release ipserver-interface 
against the indicated IPSI circuit pack.
To restore the TONE-BD to service you must execute the set tone spe 
health-override command.
1
FAIL
This IPSI or Tone-Clock circuit pack is suspected of having a clock at the 
edge of its specified frequency. A Tone-Clock circuit pack with this problem 
can cause Expansion Interface circuit packs and SNI circuit packs to go 
out-of-frame or report no neighbor conditions, thus causing EPNs, 
Expansion Archangel Links (EALs), Remote Neighbor Links (RNLs), and/or 
Local Neighbor Links LNLs) to go down.
1. Replace the IPSI or Tone-Clock circuit pack identified in the error log. 
PASS
This IPSI or Tone-Clock circuit pack has not reported a loss of clock.
Table 841: Test #46 Clock Health Inquiry Test (continued)
Error
Code
Test
Result
Description / Recommendation
 2 of 2