Communication Manager Maintenance-Object Repair Procedures
2354 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Notes:
a. Error Type 0: run the short test sequence first. If every test passes, run the long test 
sequence. Refer to each appropriate test’s description, and follow its recommended 
procedures.
b. Error Type 1: A failure in the tone generation facility on the indicated circuit pack has been 
detected. Replace the circuit pack. See 
c. Error Type 18: the IPSI or Tone-Clock circuit pack has been made unavailable using 
busyout tone-clock location. It only applies to systems which have the high- or 
critical-reliability option administered, because only a standby Tone-Clock circuit may be 
made busy by that command. To resolve this error, execute release tone-clock 
location
 for the alarmed circuit pack.
Note:
Note:
IPSI circuit packs require the location qualifier; Tone-Clock circuit packs do 
not.
d. Error Type 130: the circuit pack has been removed or has been insane for more than 
11-minutes. To clear the error, reinsert or replace the circuit pack.
e. Error Type 257: the tone generation facility is having problems verifying that tones have 
been connected as requested
f. Error Type 513: The tone generation facility may or may not be able to generate tones.
18 (
0
busyout tone-clock location
WRN
OFF
release 
tone-clock 
location
130 (
MIN
ON
test tone-clock 
location sh
257 (
) 17667
None
MIN
ON
513 (
17666
Tone Generator Audit/
Update (41)
MIN
ON
test tone-clock 
location r 3
1281 (
Any
Tone Generator Audit/
Update (41)
MIN
ON
test tone-clock 
location r 3
1. IPSI circuit packs require the location qualifier; Tone-Clock circuit packs do not.
2. MAJOR alarm if the alarmed IPSI or Tone-Clock circuit pack is not duplicated; MINOR if it is duplicated 
within the same PN.
Table 842: Tone Generator Error Log Entries (continued)
Error
Type
Aux 
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
 2 of 2