Communication Manager Maintenance-Object Repair Procedures
2358 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Table 843: Test #40 Tone Generator Transmission Test 
Error 
Code
Test 
Result
Description / Recommendation
None
ABRT
The system was not able to allocate all the resources needed for this 
test or there was an Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
1
ABRT
The system could not allocate all the resources needed to test the 
DTMF tones.
1. Retry the command at 1-minute intervals up to 5 times.
1001
ABRT
The system was not able to put the tone generation facility in the 
appropriate mode to test it.
1. Retry the command at 1-minute intervals up to 5 times.
1002
ABRT
The system could not allocate time slots for the test connection. This 
can happen when the system is heavily loaded. If the system is not 
heavily loaded, use test tdm port-network P to test the TDM 
bus.
1. Retry the command at 1-minute intervals up to 5 times.
1003
ABRT
The system could not allocate a tone receiver for the test connection. 
This can happen when the system is heavily loaded or there is not an 
IPSI or Tone Detector circuit pack in the port network where this test is 
being executed.
1. Make sure there is an IPSI or Tone Detector circuit pack in the 
same port network.
2. If the circuit pack is missing, install one in the same port network.
3. Allow approximately 1-minute for Tone Detector maintenance to 
run on the newly inserted IPSI or Tone Detector circuit pack.
4. Retry the command at 1-minute intervals up to 5 times.
1022
ABRT
Tone detection for the system is administered as wide broadband (tone 
detection mode 5), and the Tone Detector used for this test was not a 
TN420C (the only circuit pack with this capability). GPTD ports on other 
types of Tone Detector circuit packs are taken out of service since they 
cannot provide the administered function. Either:
Change the tone-detection mode administered on the 
system-parameters country-options screen.
Remove all non-TN420C circuit packs from the system.
 1 of 2