TONE-PT (Tone Generator)
Issue 1 June 2005
2361
 
Tone Generator Crosstalk Test (#90)
This test checks the ability of the Tone Generator to talk on a specific time slot. The tone 
generator is told to talk on a specific time slot. The other idle time slots are checked to make 
sure the Tone Generator put the tone on only the specified time slot.
1
FAIL
The system requires a TN780, TN2182, or TN2312 Tone-Clock circuit to 
support the administered tone-generation parameters.
1. Check the administration on the tone-generation screen. 
Specifically, the Base Tone Generation Set on page 1 and any custom 
tone administration beginning on page 2.
2. Replace any existing IPSI with a TN2312., or an existing Tone-Clock 
circuits packs with a TN780 or TN2182.
PASS
The tone generation facility has been successfully refreshed with its 
time-slot translation and system administration is consistent with this type 
of Tone-Clock.
1. Display the Hardware Error Log using display errors to make sure 
this circuit pack did not generate new errors.
Table 844: Test #41 Tone Generator Update/Audit Test (continued)
Error
Code
Test
Result
Description / Recommendation
 2 of 2
Table 845: Test #90 Tone Generator Crosstalk Test 
Error
Code
Test
Result
Description / Recommendation
None
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
1001
ABRT
The system was not able to put the tone generation facility in the 
appropriate mode to test it.
1002
ABRT
The system could not allocate time slots for the test connection. This can 
happen when the system is heavily loaded. If the system is not heavily 
loaded, then test the TDM-BUS using test tdm port-network P.
 1 of 2