Communication Manager Maintenance-Object Repair Procedures
2362 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
2000
ABRT
Response to the test request was not received within the allowable time 
period.
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
The Tone Generator could be defective. In a port network with more than 
one IPSI or Tone-Clock circuit pack, the system will attempt to move the 
tone generation function to the alternate one.
1. Test the IPSI or Tone-Clock circuit pack again using test 
tone-clock location.
2. If the test fails again, look at the Hardware Error Log for Tone Detector 
circuit pack errors.
3. If there are Tone Detector circuit pack errors, see Tone Detector 
maintenance documentation (
resolve these errors first.
4. If there are no Tone Detector circuit pack errors, then the IPSI or 
Tone-Clock circuit pack should be replaced. See 
PASS
The tone generation facility is able to put tones out.
Table 845: Test #90 Tone Generator Crosstalk Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 2 of 2