Avaya 03-300430 User Manual

Page of 2574
TTR-LEV (TTR Level)
Issue 1 June 2005
2373
 
than the threshold. These errors are typically generated during boot time or other 
transitional states when the ports are being brought into service.
d. Error Type 4: the total number of GPTD ports currently in service is below the administered 
threshold. To clear the alarm, see 
e. Error Type 5: does not indicate a current error condition. It indicates that the number of Call 
Classifier ports (CLSFY-PT) service was below the administered threshold, but is now equal 
to or greater than the threshold. These errors are typically generated during boot time or 
other transitional states when the ports are being brought into service.
f. Error Type 6: the total number of Call Classifier ports (CLSFY-PT) currently in service is 
below the administered threshold. To clear the alarm, see 
g. Error Type 7: there are currently no DTMR ports in service. To clear the alarm, see 
h. Error Type 8: there are currently no GPTD ports in service. To clear the alarm, see 
i. Error Type 9: there are currently no Call Classifier ports (CLSFY-PT) in service. To clear the 
alarm, see