Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
2380 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Incoming Dial Type
tone,
rotary,
mf (to other Avaya systems only)
Wink Timer for wink type 
300
Wink Timer for delay type
4500
Trunk Group screen, Page 3 (Administrable Timers)
Incoming Disconnect
100
Incoming Glare Guard
800ms or higher
Incoming Dial Guard
10 
Incoming Incomplete Dial Alarm
25 or higher
Incoming Partial Dial
18
PPS
10 or 20
Make (for PPS 10)
35
Break (for PPS 10)
65
Make (for PPS 20)
15
Break (for PPS 20)
35
Outgoing Disconnect
100
Outgoing Glare Guard
800 or higher
Outgoing Rotary Dial Interdigit
800 
Outgoing Seizure Response
5
Table 850: TN2242 administration  (continued)
Field
Value
 2 of 2