Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
2388 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Error Log Entries and Test to Clear Values
Table 852: DS1 Interface Circuit Pack Maintenance Error Log Entries 
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
0
Any
Any
Any
test board location
1(
0
Circuit pack removed or 
SAKI (#53) failed
WRN
MIN
ON
18(
0
busyout board location
WRN
OFF
release board 
location
23(
)
0
WRN
OFF
add ds1 location
125(
none 
or 3
None
WRN
MIN
ON
257
65535
Control Channel Loop test 
(#52)
MIN
ON
test board location 
l r 20
257(
Any
None
513(
)
Any
WRN
MIN
ON
514(
46086
WRN
MIN
ON
769(
46085
WRN
MIN
ON
770(
46096
WRN
MIN
ON
1025(
4363
NPE Audit test (#50)
1281
Any
Loss of Signal Alarm 
Inquiry (#138)
WRN
MIN
OFF
test board location
1300(
Any
Loss Of Signal Alarm 
Inquiry (#138)
WRN
OFF
test board location
1301(
Any
Loss Of Signal Alarm 
Inquiry (#138)
WRN
OFF
test board location
1302(
Any
Loss Of Signal Alarm 
Inquiry (#138)
WRN
MIN
OFF
test board location
1303 (
Any
Loss Of Signal Alarm 
Inquiry (#138)
WRN
MIN
ON
test board location
1310(
Any
Board Loopback test 
(#1209)
MIN
ON
test board location 
ds1/csu-loopback-tests