Communication Manager Maintenance-Object Repair Procedures
2392 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Aux Data 3: the 24-/32-channel option jumper setting on the circuit pack does not match 
the option set on the DS1 Circuit Pack administration screen. The circuit pack must be 
physically removed to see the setting of the jumper.
e. Error Type 257: associated with the Common Port Circuit Pack Maintenance test. See 
on page 2539 for details.
f. Error Type 513: the UDS1 Interface circuit pack has detected a transient hardware 
problem. The value in the Aux Data field indicates the type of hardware problem:
If the UDS1 board detects only one of these hardware problems, then the error will 
disappear when none of these faults are detected for 10 minutes. If the same Aux Data 
value is logged more than once in a 24-hour period, the circuit pack should be replaced.
g. Error Type 514: LAN External RAM Error. This error occurs when there is a hardware fault 
in the external RAM. The RAM is used for message buffering to and from the Packet bus. 
This error should not occur frequently. If it does (10 times within 30 minutes), the circuit 
pack should be replaced.
h. Error Type 769: transmit FIFO Underflow Error. This error occurs when the circuit pack 
cannot find the “end of frame” bit when transmitting a frame to the Packet bus. An alarm is 
raised if this error occurs three times within 10 minutes. Clear the alarm using the following 
commands: busyout board locationreset board locationtest board 
location
 longrelease board location. If the error recurs within 10 minutes, 
replace the circuit pack.
i. Error Type 770: unable to Write LAN Translation RAM Error. This error occurs when a call 
is aborted because there are no available translation RAM locations for the call connection 
attempt. An alarm is raised if this error occurs two times within 10 minutes. Clear the alarm 
using the following commands: busyout board locationreset board location
test board location longrelease board location. If the error recurs within 10 
minutes, replace the circuit pack.
j. Error Type 1300: CSU module/T1 sync splitter missing or E1 synchronization splitter 
(E1SS) missing.
CSU module/T1 sync splitter missing: The Near-End CSU Type field on the add ds1 
screen is integrated but the 120A1 CSU module or the 401A T1 sync splitter is not 
physically connected (or is improperly connected) to the UDS1 board on the back of the port 
carrier.
If using the 120A1 CSU module or the 401A T1 sync splitter, plug (or replug) the CSU 
module/T1 sync splitter into the UDS1 circuit pack’s connector on the I/O connector panel 
Aux Data
Problem
4352
External RAM failure
4353
Internal RAM failure
4355
Internal ROM failure