Communication Manager Maintenance-Object Repair Procedures
2396 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
The circuit pack is isolated from the system and every trunk or port on this circuit pack is 
placed into the out-of-service state. The system will try to restore the circuit pack within 
20-30 minutes. When no faults are detected for 20-30 minutes, the UDS1 Interface circuit 
pack is restored to normal operation. Every trunk or port of the UDS1 Interface circuit pack 
is then returned to the in-service state.
If the board is not restored to normal operation or the error recurs after the board was 
restored to normal operation, escalate the problem.
v. Error Types 3073 to 3160: for releases of G3V4 and higher, Error Type 3073 shows that 
this board is receiving slips. The Aux Data contains the last slip count reported.
w. Error Type 3330: LAN critical error. A critical failure has been detected in the Packet bus 
interface of the circuit pack. This failure may be due to an on-board fault or a Packet bus 
fault. If the Packet bus is alarmed, see 
recommended repair procedures.
This error isolates the board from the Packet bus and raises an alarm. If the Packet bus is 
not alarmed, enter busyout board locationreset board locationtest board 
location
, and release board location. This should clear the alarm and restore the 
board to the Packet bus.
If the problem persists, and there are no PKT-BUS alarms, then replace the circuit pack.
x. Error Types 3585 to 3601: for later releases of G3V4 and beyond, Error Type 3585 shows 
that this board is receiving misframes. The AUX Data contains the last misframe count 
reported.
y. Error Type 3840: not service-affecting. No action is required. These errors are reported by 
the circuit pack when it receives a bad control channel message from the switch. The 
auxiliary data identifies the following error events:
z. Error Type 3841: the UDS1 Interface circuit pack has detected a transient hardware logic 
error (for example, program logic inconsistency). This error will disappear when no faults 
are detected for 100 minutes. The value in Aux Data indicates the type of hardware 
problem.
Aux Data
Event
4096
Bad major heading
4097
Bad port number
4098
Bad data
4099
Bad sub-qualifier
4100
State inconsistency
4101
Bad logical link