Avaya 03-300430 User Manual

Page of 2574
UDS1-BD (UDS1 Interface Circuit Pack)
Issue 1 June 2005
2399
 
NPE Connection Audit Test (#50)
The system sends a message to the circuit pack’s on-board microprocessor to update the 
network-connectivity translation for its SCOTCH-NPE chip.
Internal Loop-Around test (#135)
X
D
DS1/CSU Loopback tests: 
DS1 Board Loopback test (#1209)
CSU Equipment Loopback test (#1210)
CSU Repeater Loopback test (#1211)
X
X
X
D
D
D
CPE Loop-Back Jack test (#1212)
X
D
Far CSU Loopback test (#1213)
X
D
One-Way Span test (#1214)
X
D
Inject Single Bit Error (#1215)
X
D
End Loopback/Span test (#1216)
X
D
1. D = Destructive; ND = Nondestructive
Table 853: UDS1 - Demand Test order of investigation  (continued)
Order of Investigation
Short Test
Sequence
Long Test
Sequence
Reset Board
Sequence
test ds1-loop
D/ND
1
 2 of 2
Table 854: Test #50 NPE Connection Audit Test 
Error
Code
Test
Result
Description / Recommendation
None
2100
ABRT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1019
ABRT
The test aborted because a test was already running on the port.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
PASS
The circuit pack’s SCOTCH-NPE chip has been updated with its 
translation.
 1 of 2