Avaya 03-300430 User Manual

Page of 2574
UDS1-BD (UDS1 Interface Circuit Pack)
Issue 1 June 2005
2413
 
1303
FAIL
The UDS1 circuit pack Suffix is incorrect for CSU module/T1 sync splitter 
or E1 Sync Splitter administration.
The UDS1 circuit pack Suffix is incorrect for CSU module/T1 sync splitter 
administration. The Near-End CSU Type field on the add ds1 screen 
has been administered as integrated but the UDS1 circuit pack is not a 
TN464F or higher suffix UDS1 board.
1. If the CSU module/T1 sync splitter is to be used, and the Near-End 
CSU Type field is set to integrated to allow for CSU module/T1 sync 
splitter administration, remove the circuit pack and replace it with a 
TN464F or higher suffix board. Otherwise, use change ds1 to set 
the Near-End CSU Type field to other.
The UDS1 circuit pack Suffix is incorrect for E1 Sync Splitter 
administration. The E1 Sync-Splitter? field on the add ds1 screen has 
been administered as y but the UDS1 circuit pack is not a TN464F or 
higher suffix UDS1 board.
1. If the E1 Sync Splitter is to be used, and the E1 Sync-Splitter field is 
set to y to allow for E1SS administration, remove the circuit pack and 
replace it with a TN464F or higher suffix board. Otherwise, use 
change ds1 to set the E1 Sync-Splitter field to n.
1310
FAIL
The UDS1 Board Loopback (BLB) demand test (#1209) failed.
1. Repeat the test using test ds1-loop location ds1/
csu-loopback-tests
2. If the BLB test continues to fail, then replace the UDS1-BD circuit 
pack.
3. Run this test again.
Table 858: Test #138 Loss of Signal Alarm Inquiry Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 5 of 9