UDS1-BD (UDS1 Interface Circuit Pack)
Issue 1 June 2005
2437
 
Table 864: Test #144 Slip Alarm Inquiry Test 
Error
Code
Test
Result
Description / Recommendation
 
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
2000
ABRT
Response to the test was not received within the allowable time period. 
This may be due to hyperactivity. Error Type 1538 in the error log 
indicates hyperactivity. The hyperactive circuit pack is out of service, 
and one or more of the following symptoms may be exhibited.
1. The UDS1-BD tests (such as Tests #138 and #139) are aborting 
with Error Code 2000.
2. The tests run on the ports of this circuit pack are returning a 
no-board result.
3. A busyout or a release command has no effect on the test 
results.
4. A list config shows that the circuit pack and its ports are 
properly installed.
When hyperactivity occurs, the circuit pack is isolated from the system, 
and all of its trunks are placed into the out-of-service state. The system 
will try to restore the circuit pack within 15 minutes. When no faults are 
detected for 15 minutes, the UDS1 interface circuit pack is restored to 
normal operation. Every UDS1 Interface trunk is then returned to the 
in-service state. Hyperactivity is often caused by the associated facility. 
In such a case, faults (such as slips, misframes, or blue alarms) would 
be entered in the error log. In addition, many hardware errors would be 
logged against the associated trunk circuits. If the facility is OK and the 
error occurs again after 15 minutes, replace the circuit pack.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.