UDS1-BD (UDS1 Interface Circuit Pack)
Issue 1 June 2005
2439
 
1 to 88
FAIL
(
cont’d
)
If the UDS1 connects to a line-side terminating device (for example, a 
PRI terminal adapter), do the following:
1. Retry the command at 1-minute intervals up to 5 times.
2. Enter list measurement ds1-log location to read the 
error seconds measurement.
3. Verify that the switch DS1 and the line-side terminating device are 
administered using the same signaling mode, framing mode, and 
line coding.
4. Investigate the maintenance status of the line-side terminating 
device.
5. Contact the vendor of the line-side terminating device to diagnose 
the equipment.
6. Check the physical connection of the UDS1 interface circuit pack to 
the terminating device, and check the premise distribution system 
(or the intra-premise wiring) for physical connection failures.
7. Replace the local UDS1 interface circuit pack and repeat the test.
 
PASS
No Slip alarm is detected on the UDS1 Interface circuit pack.
0
NO 
BOARD
The test could not relate the internal ID to the port (no board). This 
could be due to incorrect translations, no board is inserted, an incorrect 
board is inserted, or an insane board is inserted.
1. Verify that the board’s translations are correct. Execute add ds1 
location to administer the UDS1 interface if it is not already 
administered.
2. If the board was already administered correctly, check the error log 
to determine whether the board is hyperactive. If so, the board was 
shut down. Reseating the board will re-initialize it.
3. If the board was found to be correctly inserted in step 1, enter 
busyout board location.
4. Enter reset board location.
5. Enter release board location.
6. Enter test board location long.
This should re-establish the linkage between the internal ID and the port.
Table 864: Test #144 Slip Alarm Inquiry Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 3 of 3