UDS1-BD (UDS1 Interface Circuit Pack)
Issue 1 June 2005
2453
 
1015
ABRT
Ports on the UDS1 Interface circuit pack have not been busied out to 
out-of-service.
1. Enter busyout board location to put each trunk or port of the 
UDS1 Interface circuit pack into the out-of-service state.
2. Retry the command.
1039
ABRT
The UDS1 Interface circuit pack is providing timing for the system. 
Executing this test could cause major system disruption.
If the UDS1 Interface circuit pack needs to be tested, set the 
synchronization reference to another DS1 Interface circuit pack or to the 
IPSI or Tone-Clock circuit pack via the following command sequence:
1. Enter disable synchronization-switch.
2. Enter set synchronization location.
3. Enter enable synchronization-switch.
Rerun the test. If the test aborts again, a different ABRT code will be 
generated. Follow the recommended maintenance procedures for the Error 
Code. 
1950
ABRT
Another loopback/span test is already executing on the DS1 board or the 
board is in a network-requested loop-back mode (line loopback or payload 
loopback). The hardware error log will indicate whether a Customer 
Loop-Back Jack test, Far CSU Loopback test, or the One-Way Span test is 
executing or if the board is in line-loopback or payload-loop-back mode. 
Only one long-duration loopback/span tests can be active at a given time. 
Thus, if a loopback/span test is already active, that test must be terminated 
using test ds1-loop location end-loopback/span-test in 
order to execute this test.
1951
ABRT
The CSU Repeater Loopback test could not be executed because the 
120A1 CSU module or the 401A T1 sync splitter was not physically 
installed. Physically connect the 120A1 CSU module or the 401A T1 sync 
splitter to the UDS1 board on the back of the port carrier.
Table 869: Test #1211 CSU Repeater Loop-Back Test  (continued)
Error
Code
Test
Result
Description / Recommendation