Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
2454 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
2000
ABRT
Response to the test was not received within the allowable time period. 
This may be due to hyperactivity. Error Type 1538 in the error log 
indicates hyperactivity. The hyperactive circuit pack is out of service, and 
one or more of the following symptoms may be exhibited.
1. The UDS1-BD tests (such as Tests #138 and #139) are aborting with 
Error Code 2000.
2. The tests run on the ports of this circuit pack are returning a no-board 
result.
3. A busyout or a release command has no effect on the test results.
4. A list config shows that the circuit pack and its ports are properly 
installed.
When hyperactivity occurs, the circuit pack is isolated from the system, and 
all of its trunks are placed into the out-of-service state. The system will try 
to restore the circuit pack within 15 minutes. When no faults are detected 
for 15 minutes, the UDS1 interface circuit pack is restored to normal 
operation. Every UDS1 Interface trunk is then returned to the in-service 
state. Hyperactivity is often caused by the associated facility. In such a 
case, faults (such as slips, misframes, or blue alarms) would be entered in 
the error log. In addition, many hardware errors would be logged against 
the associated trunk circuits. If the facility is OK and the error occurs again 
after 15 minutes, replace the circuit pack.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
 
FAIL
UDS1 Interface circuit pack failed the CSU Repeater Loopback test.
1. Retry test ds1-loop location ds1/csu-loopback-tests
2. If the RLB test continues to fail, and the CSU Equipment Loopback 
test (#1210) passed, then replace the CSU module/T1 sync splitter.
 
PASS
The RLB test executed successfully. The test pattern was transmitted and 
received successfully over the connection from the UDS1 board to the 
far-edge of the 120A1 CSU module or the 401A T1 sync splitter.
Table 869: Test #1211 CSU Repeater Loop-Back Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 3 of 4