UDS1-BD (UDS1 Interface Circuit Pack)
Issue 1 June 2005
2459
 
3
FAIL
The CPE Loop-Back Jack test was not set up properly. The framed 3-in-24 
test pattern, generated by the UDS1 Interface circuit pack and looped 
back through the CPE Loop-Back Jack, could not be detected properly by 
the UDS1 circuit pack.
1. Retry test ds1-loop location 
cpe-loopback-jack-test-begin
2. If the CPE Loop-Back Jack test continues to fail, the problem could be 
with the UDS1-BD board, the CPE Loop-Back Jack equipment, or 
somewhere in between. Run test ds1-loop location ds1/
csu-loopback-tests
 to see if the loop-back tests closer to the 
UDS1-BD board are successful. If any of those loop-back tests fail, 
follow the maintenance strategy associated with those loopbacks.
 
PASS
The CPE Loop-Back Jack test has successfully begun executing. The test 
will continue to run until the system technician enters test ds1-loop 
location end-loopback/span-test or release board location
0
NO
BOARD
The test could not relate the internal ID to the port (no board). This could 
be due to incorrect translations, no board is inserted, an incorrect board is 
inserted, or an insane board is inserted.
1. Verify that the board’s translations are correct. Execute add ds1 
location to administer the UDS1 interface if it is not already 
administered.
2. If the board was already administered correctly, check the error log to 
determine whether the board is hyperactive. If so, the board was shut 
down. Reseating the board will re-initialize it.
3. If the board was found to be correctly inserted in step 1, enter 
busyout board location
4. Enter reset board location.
5. Enter release board location.
6. Enter test board location long.
This should re-establish the linkage between the internal ID and the port.
Table 870: Test #1212 CPE Loop-Back Jack Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 4 of 4