Avaya 03-300430 User Manual

Page of 2574
UDS1-BD (UDS1 Interface Circuit Pack)
Issue 1 June 2005
2461
 
1005
ABRT
Far CSU Loopback test cannot be executed in the current configuration. To 
run this test, the TN464F or higher suffix UDS1 must be administered for 
24-channel operation. The Bit Rate field on the DS1 circuit pack 
administration screen must be set to 1.544 for 24-channel operation.
1015
ABRT
Ports on the UDS1 Interface circuit pack have not been busied out to 
out-of-service.
1. Enter busyout board location to put each trunk or port of the 
UDS1 Interface circuit pack into the out-of-service state.
2. Retry the command.
1039
ABRT
The UDS1 Interface circuit pack is providing timing for the system. 
Executing this test could cause major system disruption.
If the UDS1 Interface circuit pack needs to be tested, set the 
synchronization reference to another DS1 Interface circuit pack or to the 
IPSI or Tone-Clock circuit pack via the following command sequence:
1. Enter disable synchronization-switch.
2. Enter set synchronization location.
3. Enter enable synchronization-switch.
Rerun the test. If the test aborts again, a different ABRT code will be 
generated. Follow the recommended maintenance procedures for the 
Error Code. 
1950
ABRT
Another loopback/span test is already executing on the DS1 board or the 
board is in a network requested loop-back mode (line loopback or payload 
loopback). The hardware error log will indicate whether a Customer 
Loop-Back Jack test, Far CSU Loopback test, or the One-Way Span test is 
executing or if the board is in line-loopback or payload-loop-back mode. 
Only one long-duration loopback/span test can be active at a given time. 
Thus, if a loopback/span test is already active, that test must be terminated 
using test ds1-loop location end-loopback/span-test in 
order to execute this test.
Table 871: Test #1213 Far CSU Loop-Back Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 2 of 4