Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
2466 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
2000
ABRT
Response to the test was not received within the allowable time period. 
This may be due to hyperactivity. Error Type 1538 in the error log indicates 
hyperactivity. The hyperactive circuit pack is out of service, and one or 
more of the following symptoms may be exhibited.
1. The UDS1-BD tests (such as Tests #138 and #139) are aborting with 
Error Code 2000.
2. The tests run on the ports of this circuit pack are returning a no-board 
result.
3. A busyout or a release command has no effect on the test results.
4. A list config shows that the circuit pack and its ports are properly 
installed.
When hyperactivity occurs, the circuit pack is isolated from the system, and 
all of its trunks are placed into the out-of-service state. The system will try 
to restore the circuit pack within 15 minutes. When no faults are detected 
for 15 minutes, the UDS1 interface circuit pack is restored to normal 
operation. Every trunk for the UDS1 interface circuit pack is then returned 
to the in-service state. Hyperactivity is often caused by the associated 
facility. In such a case, faults (such as slips, misframes, or blue alarms) 
would be entered in the error log. In addition, many hardware errors would 
be logged against the associated trunk circuits. If the facility is OK and the 
error occurs again after 15 minutes, replace the circuit pack.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
 
PASS
The One-Way Span test has successfully began transmitting a framed 
3-in-24 test pattern. The runs until the system technician enters test 
ds1-loop location end-loopback/span-test or release board 
location.
Table 872: Test #1214 One-Way Span Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 3 of 4