Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
2496 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Receive FIFO Overflow Error Counter Test (#596)
This test is nondestructive. When the VAL circuit pack detects packet bus buffer overflow, it 
increments the error on the FIFO Overflow error counter. This test reads and clears the counter. 
If errors are occasional, then they can be due to statistical buffer sizing.
Table 883: Test #596 Receive FIFO Overflow Error Counter Test 
Error
Code
Test
Result
Description / Recommendation
2000
ABRT
Did not receive circuit pack test response within the allowable time period.
1. Retry command at 1-minute intervals up to 5 times.
2. If the problem persists, reset the circuit pack (reset board 
location).
3. If the problem persists, replace the circuit pack.
2100
ABRT
Could not allocate the necessary system resources to run test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the problem persists, escalate the problem.
2500
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
2. If the problem persists, escalate the problem.
1–10
FAIL
Circuit pack detects overflow errors. The Error Code indicates the value of 
the on-board error counter.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to fail, execute the Packet Interface test (#598) 
(test board location).
3. If Packet Interface test (#598) fails, see repair procedures for Test 
#598.
PASS
Circuit pack detects no errors.