2520 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
1002
ABRT
The system could not allocate time slots for the test, the traffic load on the 
system is very high, or time slots are out-of-service due to TDM-BUS 
errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic, 
retry the command at 1-minute intervals up to 5 times.
1003
ABRT
The system could not allocate a Tone Detector for the test, the system is 
oversized for the number of Tone Detectors present, or some Tone 
Detectors are out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up 
to 5 times.
1004
ABRT
The port has been seized by a user for a valid call. Use status station 
for the station associated with this port and determine whether the port is 
available for testing.
1. Retry the command at 1-minute intervals up to 5 times.
2000
ABRT
Response to the test request was not received from the VC-BD circuit pack 
within the allowable time period.
1. If this result occurs repeatedly, reset the circuit pack if the other ports 
are idle by using busyout port location and reset port 
location
.
2. If this result occurs again, replace the circuit pack.
2012
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
0, 1
FAIL
The VC-DSPPT DSP Loopback test failed.
1. Replace the circuit pack.
PASS
The VC DSPPT DSP Loopback test passed
Table 894: Test #1105 VC-DSP Port DSP Loop-Back Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 2 of 2