Each Voice Conditioner circuit pack (VC-BD) provides two types of resources:
Transcoder Resources that are used for encoding and decoding audio formats
Summer Resources that are used for summing audio formats from different sources.
The Voice Conditioner Summer ports (VC-SUMPT) are the summer resources on the VC-BD. 
There are 8 such ports on a VC-BD.
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 0
run the short test sequence first. If every test passes, run the long test sequence. Refer to 
each appropriate test’s description, and follow its recommended procedures.
b. Error Type 18: this port has been busied out with busyout port location.
c. Error Type 130: the circuit pack has been removed or has been insane for more than 
11 minutes. To clear the error, replace or reinsert the circuit pack.
MO Name
Alarm Level
Initial SAT Command to Run
Full Name of MO
VC-SUMPT
MAJ
test port location
Voice Conditioner Summer Port
VC-SUMPT
MIN
test port location
Voice Conditioner Summer Port
VC-SUMPT
WRN
test port location
Voice Conditioner Summer Port
Table 897: VC-SUMPT Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
Any
Any
Any
test port location sh r 1
18 (
0
busyout port location
WRN
OFF
release port location
130 (
WRN
ON
test port location sh
257 (
)
Any
Control Channel Loop test 
(#52)
MIN
ON
test board location 1 r 3
513 (
)
Any
VC Summer Port Local 
Loopback test (#1100)
MIN
ON
test board location sh r 3