Wideband Access Endpoint interface, and because faults can occur end-to-end, 
troubleshooting procedures based on an end-to-end view of the network is required.
Wideband access endpoint port maintenance provides a strategy to maintain a wideband 
access endpoint port via a port on the Universal DS1 interface circuit pack or the MM710 DS1 
Interface Media Module hardware. The maintenance strategy covers logging wideband access 
endpoint port hardware errors, running tests for port initialization, periodic and scheduled 
maintenance, demand tests, and alarm escalation and resolution. Two different port service 
states are specified in the wideband access endpoint port maintenance:
out-of-service: the port is in a deactivated state and cannot be used for calls
in-service: the port is in an activated state and can be used for calls
If the UDS1 Interface circuit pack or the MM710 DS1 Interface Media Module is out of 
service, every port on it is taken out of service, and a Warning alarm is raised.
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 18: the wideband access endpoint has been busied out by busyout 
access-endpoint extension. No calls can be made to this extension.
Table 900: Wideband Access Endpoint Maintenance Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate 
test’s description, and follow its recommended procedures.
0
Any
Any
Any
test access-endpoint extension 
sh r 1
18 (
)
0
busyout access-endpoint 
extension
WRN
OFF
release access-endpoint 
extension
130 (
None
WRN
ON
test access-endpoint extension
1281 (
Conference Circuit (#7)
MIN
ON
test access-endpoint extension l 
r 4
1537 (
NPE Crosstalk Test (#6)
MIN
ON
test access-endpoint extension l 
r 3
1793 (
None
test board location long
3840 (
Any
Port Audit and Update (#36)