Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
2544 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Error Log Entries and Test to Clear Values 
Notes:
a. Error Type 1: the circuit pack or media module stopped functioning or has been physically 
removed from the system. This Error Type does not apply to ANN-BD, DETR-BD, 
S-SYN-BD, M/T-BD, or CLSFY-BD. The alarm is logged approximately 11 minutes after 
removal of the circuit pack or failure of the SAKI Sanity Test (#53).
Check for the physical presence of the circuit pack or media module in the slot indicated by 
the alarm. If the circuit pack or media module is absent, insert one of the proper type. If the 
circuit pack or media module is present and its red LED is lit, se
Table 907: Common Port Circuit Pack Maintenance Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each 
appropriate test’s description, and follow its recommended procedures.
0
Any
Any
Any
test board location sh r 1
1 (
0
Circuit pack or Media Module 
removed or SAKI Sanity (#53)
MIN
ON
18 (
0
busyout board location
WRN
OFF
release board location
23 (
)
0
None
WRN
OFF
36 (
4368
none
125 (
None
MIN
ON
217 (
)
0
None
WRN
ON
257 (
65535
Control Channel Test (#52)
MIN
ON
test board location sh r 20
267 (
0
None
WRN
ON
513 (
Any
None
MIN
ON
test board location sh
769 (
4358
None
1025 (
)
4363
NPE Audit Test (#50)
test board location l r 20
1281 (
Ringing Application Test (#51)
MIN
ON
test board location r 2
1538 (
)
Any
None
WRN 
MIN
ON
1793 (
Neon Test (#220)
MIN
ON
test board location r 2
3840 (
Any
None
3999 (
Any
None