Communication Manager Maintenance-Object Repair Procedures
2546 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
k. Error Type 1025: this error is not service-affecting and no action is required.
l. Error Type 1281: no ringing current is detected. Run Test #51, Ringing Application Test, 
and follow the procedures for Test #51. 
G700
: On the G700, the associated test for this Error 
Type aborts with Error Code 1412.
m. Error Type 1538: the hyperactive circuit pack or media module is out-of-service and may 
exhibit one or more of the following symptoms:
1. The common circuit pack/media module level tests such as Test #51 and/or Test #220 
are aborting with Error Code 2000.
2. The tests run on the ports of this circuit pack or media module are returning with a 
NO-BOARD.
3. A busyout/release of the circuit pack or media module has no effect on test results.
4. A list configuration command shows that the circuit pack or media module and 
ports are properly installed.
If the XXX-BD is not a TN754 Digital Line Circuit Pack (DIG-BD) or Digital Line Media 
Module, and if this error happens again within 15 minutes, then replace the circuit pack or 
media module. If the XXX-BD is a TN754 Digital Line Circuit Pack (DIG-BD) or Digital Line 
Media Module, then check the alarm level. If the alarm level is a WARNING, this indicates 
that users are probably causing the hyperactivity by adjusting or changing their digital 
stations. If the circuit pack or media module is very hyperactive, then this alarm will be 
upgraded to a MINOR alarm within 1 hour. If the alarm level is a MINOR alarm, then replace 
the circuit pack or media module.
n. Error Type 1793: no neon current is detected. Run test board location short and 
follow the procedures for Test #220. This error applies to TN769 and TN746 Analog Line 
circuit packs and to MM711 Analog Line Media Modules.
o. Error Type 3840: this error is not service-affecting and no action is required.
p. Error Type 3999: the circuit pack or media module sent a large number of control channel 
messages to the switch within a short period of time. If Error Type 1538 is also present, then 
the circuit pack or media module was taken out-of-service due to hyperactivity. If Error Type 
1538 is absent, then the circuit pack or media module was not taken out-of-service, but it 
has generated 50% of the messages necessary to be considered hyperactive. This may be 
completely normal during heavy traffic periods. However, if this Error Type is logged when 
the circuit pack or media module is being lightly used, it may indicate a problem with the 
circuit pack or media module, or the equipment attached to it.