Communication Manager Maintenance-Object Repair Procedures
2556 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
ABRT
Could not allocate the necessary system resources to run this test. Internal 
system error.
1. If Error Type 1538 is present in the Error Log, follow the recommended 
maintenance strategy.
FAIL
The test failed because no neon current was detected.
1. Determine if there is a TN755 or TN752 power unit circuit pack 
installed in the same carrier as the TN746 or TN769 analog line circuit 
pack that failed the test. Look for the failure of test 220 on other TN746 
or TN769 circuit packs in the carrier. If test 220 fails on the other circuit 
packs, replace the TN755 or TN752 power unit circuit pack.
2. Retry the command again.
3. If the test continues to fail, replace the circuit pack.
4. Retry the command again.
PASS
This circuit pack is a TN746 or TN769 Analog Line circuit pack and the neon 
current is detected. If this test passes, it can also mean that this circuit pack 
is not a TN746 or TN769 Analog Line circuit pack.
Any
NO 
BOARD
This is normal if the test is being done when (a) the board is not physically 
in the system or (b) the system is booting up. Otherwise, there is some 
inconsistency between the physical configuration and the data kept in the 
system.
1. Verify that the board is physically in the system.
2. Verify that the system is not in a stage of booting up.
3. Retry the command at 1-minute intervals up to 5 times.
Table 913: Test #220 Neon Test  (continued)
Error
Code
Test
Result
Description / Recommendation