Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
340 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
AC Power Query Test (#78)
AC Power Query Test (#78) is not valid for DC-powered cabinets and should always abort or 
pass. 
S8700 IP
 will always abort.
Table 91: Test #78 Power Query Test 
Error 
Code
Test 
Result
Description / Recommendation
1000
ABRT
System resources required to run test are not available.
100 
2000
ABRT
Response to the test request was not received within the allowable 
time period.
1. Retry the command at 1-minute intervals up to 5 times.
2029 
2319 
2320 
2500
ABRT
Internal system error.
S8700 MC
:
1. Retry the command at 1-minute intervals up to 5 times.
S8700 MC
Any
FAIL
A PN’s Maintenance circuit pack is incorrectly reporting an AC power 
problem. If this test fails, there is a problem with a Maintenance circuit 
pack. Replace the suspected circuit pack, and run the test again.
S8700 MC
PASS
Since this test is invalid for DC-powered cabinets, this result simply 
indicates that a PN’s Maintenance circuit pack is handling this test 
properly.